The fire and sprinkler systems function together to protect the lives and property within the building. Knowledge of Fire and Sprinkler Systems in West Vancouver entails the knowledge of the components that detect heat or smoke and the components that extinguish the fire.
The following guide covers everything from the detection of the heat by sprinkler systems, different types of systems, information regarding requirements and maintenance for the owners, among others.
Fire protection systems are composed of the detectors, alarms, and sprinklers that detect a fire, alert you, and help slow the fire down. Each component performs a specific task, but they are most effective when working together. Sprinklers control or suppress at an early stage, which ensures that people can escape and firemen can respond to the fire.
Generally speaking, buildings combine a sprinkler system with an alarm system. It is of utmost importance that fire alarm system installation complies with the BC Building Code and CAN/ULC-S524. Understanding what each component does makes your future decisions concerning your property much simpler.
Fire sprinkler systems consist of pipes, valves, and heads, and the head operates independently from other heads.
In each sprinkler head there is a glass bulb that is filled with liquid expanding when air around becomes hot enough. Bulbs come in different colours for different temperature ratings. A common red bulb breaks at about 68°C. In some sprinklers, there is a fusible link consisting of metal that will melt at a certain temperature. Smokes do not operate any heads; thus, burnt toast won’t set off sprinklers.
When the bulb breaks, the plug is falling out and the water starts to move through the open head. The deflector plate is spreading the water over the area beneath it. Simultaneously, the flow switch detects flowing water and notifies alarm system about it. That signal is sent to monitoring center that calls fire fighters.
No, and movies get this wrong. How Fire Sprinkler Systems Activate During a Fire depends on heat at each head, so only the sprinklers near the flames open. Often just a few heads control the blaze. That limits water damage and keeps the rest of the building protected.
Automatic fire sprinkler systems fall into four main types, and the right one depends on heating, building use, and fire risk.
Wet pipe systems are always filled with water so that they activate at the moment that a sprinkler head opens. This system is used more often in heated structures like offices or hotels since it has the least number of components; thus, it’s easy to perform maintenance.
The dry fire sprinkler system contains nitrogen or air instead of water. When a sprinkler head opens, air escapes, causing the valve to open and water to flow into the pipes. This type of system is preferred in cold areas because water in the pipes has a tendency to freeze.
A pre-action system is a secondary safety measure which should be applied before water flows into the pipes. A pre-action system needs two triggers: a detector signal opens the valve and fills the pipes, and heat then opens the sprinkler head; that guarantees that the system will not accidentally discharge water.
This type of sprinkler system uses open heads without any bulbs on them. This means that all the sprinklers will activate when the valve is activated. This sprinkler system is used to protect high-hazard places like fuel storage and aircraft hangars, where fires spread very quickly.
There are certain hazards at West Vancouver locations which make immediate fire suppression particularly critical.
Sprinklers reduce the risk of heat and smoke that threaten your life when evacuating. They will also help protect assets, documents, and the building itself. In case of a commercial building, this could mean faster resuming of operations after the fire.
The fire grows rapidly in the first minutes of burning, which is why prompt fire extinguishing is crucial. Hilly terrain and narrow streets of the North Shore area may delay the arrival of firefighters; a sprinkler system will operate independently throughout that period.
Sprinklers should be used together with proper procedures. The current fire safety plans show occupants where the exits, alarms, and sprinkler control valves are located. The BC Building Code requires sprinklers in many larger and higher-risk buildings. The BC Fire Code covers their ongoing maintenance. Check yours whenever a major renovation has been done.
An alarm system and sprinkler system solve different issues, so one cannot replace the other. An alarm detects a fire and alerts people. The sprinkler extinguishes it. The table below indicates where each can be used.
|
Feature |
Fire alarm system |
Fire sprinkler system |
|
Main job |
Detects fire and warns occupants |
Applies water to control the fire |
|
Triggered by |
Smoke, heat, or a pull station |
Heat at an individual head |
|
Response |
Sounds alarms and notifies the fire department |
Discharges water on the fire area |
|
Limit |
Doesn’t stop the fire |
Doesn’t warn people unless linked to an alarm |
Fire sprinkler requirements vary according to your building size, type, and age. Please verify with the District of West Vancouver what applies to your property.
The BC Building Code requires fire sprinklers in certain sizes and types of buildings, and the District may require additional requirements. The installation of fire sprinkler piping must meet NFPA 13, the standard the BC Building Code references. Ask your designer early in the design process since layout affects ceiling, mechanical space, and cost.
Fire sprinkler permits are required before work commences. A certified fire sprinkler fitter installs the system, and the inspection is done after to confirm compliance before accepting the work. Save the final report because future buyers and insurance companies will ask for it. Consult the District for the latest permit process.
The owner is responsible for making sure that systems function properly. NFPA 25 provides the testing and inspection schedule, and documentation is required. A fire sprinkler inspection checklist will help you to perform your monthly checkup easily:
Control valves are open and locked.
Pressure gauges are within the normal range.
Nozzles are clean, not damaged and unpainted.
Storage is kept at least 45 cm under the heads.
No leaks or corrosion in pipes.
Fire sprinkler system maintenance ensures that minor faults do not become major failures in the event of a fire. Professionals undertake the process, but the self-inspection fills the gaps in between.
A fire sprinkler inspection helps in ensuring that the system will work as required during an emergency. The inspection includes testing of alarm devices, checking of the valves, testing of the water flow and examination of the sprinklers. Documenting the information is also done by the technician since insurance companies and fire authorities might require them. If you skip one year, you could have corrosion and valve closure issues.
Painted or corroded heads, control valves being closed, and spray patterns being obstructed are some of the common problems. Moisture in dry systems could cause internal corrosion of the pipes. Joint leakage and low pressure readings are some other common faults.
A technician should be called when there has been any alarm activation, water leakage, or shutdown of the sprinkler system and during renovations that occur close to a fire sprinkler system. Fire sprinkler system repair services will restore the safety of the building and keep your paperwork up-to-date.
Not normally, according to the BC Building Code, but check with your local government, because some have additional requirements. Otherwise, residential systems conforming to NFPA 13D are an option. These are designed for one- and two-family dwellings and are simpler than commercial systems.
Very unlikely. Sprinklers operate on heat, and thus accidental prevalence of sprinklers happens due to physical damage, manufacturing defects, or problems of freezing pipes. Make sure ladders, forklifts, and other equipment do not obstruct the sprinkler head, and consult your specialist in case of damage.
Generally no. A single sprinkler head releases far less water than a fire hose, and activates early, before the fire grows large. One sprinkler head usually causes less damage than fire and smoke damage throughout multiple rooms.
Small properties may take a few hours, whereas large properties may take a full day or longer. It all depends on the size of the system, the type of the system, and the accessibility of the equipment. Consult your technician for the estimated time before booking.
Fire and sprinkler systems provide the best protection for the homes and buildings of West Vancouver when all its components are operating together. The detectors and alarm system alert you to a potential hazard early on, and the sprinklers confine the fire until the authorities arrive. Maintenance and inspections will ensure that all these components work properly when needed.
Are you ready for your inspection appointment? Otis Fire Protection offers more than 12 years of experience in fire protection and safety training in the Vancouver region and the Lower Mainland, completing more than 350 projects each year. Contact us today to schedule your fire sprinkler inspection in West Vancouver.